Loading...
Short answer: a mechanically interlocked socket makes it impossible to unplug under load — the plug can only be withdrawn after the switch is in the OFF position. Specify it in this order: interlock type, pin configuration, current rating, voltage and colour code, IP rating, and whether you need overcurrent or RCD protection built in. Hefeng Electric manufactures mechanically interlocked switched sockets from 16A / 32A / 63A to 125A, in 3P+N+E and other pin configurations, from 2,000+ in-house moulds.
An interlocked socket couples the switch and the plug mechanically. With the plug in and the switch ON, the mechanism physically blocks the plug from being pulled out. The sequence is always: switch OFF → unplug. This is a safety requirement on construction sites, in factories and on temporary distribution, where unplugging a loaded circuit can draw an arc and injure the operator.
It is worth distinguishing the two common terms buyers use:
| Term | What it means | When to specify it |
|---|---|---|
| Mechanical interlock | Plug cannot be withdrawn while the switch is ON; switching OFF releases the plug | Standard safety on site and industrial distribution |
| Switched socket (interlocked) | The socket has its own ON/OFF switch mechanically linked to the plug release | When the socket itself must isolate the load |
Both are available across Hefeng Electric's 16A / 32A / 63A / 125A interlocked range. If your drawing calls for a particular switching device inside the housing, send us the part number and we will confirm the equivalent.
Most three-phase interlocked enquiries specify 3P+N+E (5-pin) — three phases, neutral and earth. For a 400V supply the IEC 60309 colour is red with a 6h clock position. These three details (pin count, colour, clock position) together identify the mating plug; a 5-pin red 6h socket will not accept a differently clocked plug even at the same current rating.
When you write the RFQ, include the pin configuration, voltage, frequency and clock position together. That single line removes most of the back-and-forth before a quotation can be issued.
Mechanical interlocks are most common at 16A, 32A, 63A and 125A. Lower ratings serve tools, site cabins and small distribution; 63A and 125A serve larger temporary boards, generators and machinery feeds. Hefeng Electric covers the full range — 16A / 32A / 63A / 125A / 200A / 400A / 630A — in interlocked sockets, wall mounted sockets, panel mounted sockets, plugs and connectors, all from our own tooling.
Enquiries sometimes specify a rating between our standard steps. Rather than quote against a part number we cannot supply, we ask for the existing part number, a drawing or the load to be carried, then map it to the nearest standard rating. That detail in the first email saves a full round of correspondence.
The IP rating applies to the mated assembly — socket, plug, cable gland and lid — not the socket body alone. For outdoor and washdown areas specify IP67; for protected indoor distribution IP44 may be sufficient. Hefeng Electric interlocked sockets are available in IP44 and IP67.
Where the circuit needs additional protection, interlocked housings can be supplied with built-in overcurrent protection (MCCB or fuse holder) or with an RCD (30mA). Tell us which protection you require, or send the existing housing part number, and we will propose the matching configuration.
A complete enquiry for an interlocked socket normally includes:
| Item | Example |
|---|---|
| Interlock type | Mechanically interlocked switched socket |
| Pin configuration | 3P+N+E (5-pin) |
| Current rating | 32A / 63A / 125A |
| Voltage, frequency, clock position | 380-440V, 50/60Hz, 6h red |
| IP rating | IP67 for outdoor / washdown |
| Protection | With or without MCCB / RCD 30mA |
| Quantity and target market | So we can shortlist the right models |
Sending these seven lines together lets us return a factory-direct quotation in one step instead of asking you to repeat the specification.
No. The mechanical interlock physically blocks withdrawal until the switch is moved to OFF. That is the purpose of the mechanism.
Yes. Trade language counts pins (5-pin); the standard counts poles (3P+N+E = three phases, neutral, earth). Both describe the same socket.
Red, with a 6h clock position. Blue is used for 200-250V and yellow for 100-130V.
Our full range runs to 630A. Mechanical interlocks are most common at 16A-125A; for higher ratings tell us the application and we will propose the matching solution.
Yes. Hefeng Electric offers OEM and private label supply, including logo marking, from 2,000+ in-house moulds.
Hefeng Electric is a manufacturer of IEC 60309 industrial plugs, sockets and connectors, with 2,000+ in-house moulds and a full range from 16A to 630A. Factory direct: CE to EN IEC 60309-1/-2:2022, RoHS, CCC, CQC, ISO 9001; IP44 and IP67; OEM and private label welcome; standard items ship in 7 days.
WhatsApp +86 136 0077 7025 | sales@electroconn.com | www.electroconn.com
#IndustrialPlugs #IEC60309 #InterlockedSocket #IP67 #FactoryDirect #HefengElectric #ElectricalWholesaler